MRS*PET/CT 80

MRS*PET/CT 80

Mice, Rats and Marmosets imaging

The MRS*PET/CT 80 is a floor standing preclinical system. The CT has a variable zoom achieving 5 µm resolution in-vivo / ex-vivo. The PET component can be moved from the CT to the MR in less than 5 minutes for PET/MR imaging.

  1. This  PET/CT is based on the MRS*CT 80 and the  MRS*PET CLIP-ON 80.
  2. The PET CLIP-ON technology compatible with cryogen-free MR up to 9.4T
  3. Field of view: Axial ≤ 150mm , transaxial 80 mm, Inner diameter 112 mm

See all MRS*PET/CT models

System Details

Main Specifications

Animal type Mice, Rats, & Marmosets
PET/CT System type Floor stand
PET component MRS*PET-CO 80 (CLIP-ON)
CT component MRS*CT 80
PET CLIP-ON removable from CT Yes
PET CLIP-ON attachable to MR Yes, for sequential PET/MR Imaging

PET Specifications

Inner diameter & transaxial FOV (mm) 112 mm (ID) & 80 mm tFOV
Axial FOV (mm)  50.4 mm – 102.48 mm – 150.40 mm
Extended axial FOV (mm) 300 mm with motorised bed
PMT & Detectors configuration Silicon PM, Continuous detectors
Crystal material & Thickness (mm) Double Layers, LYSO/LYSO, 10 mm
Spatial Resolution with 3D OSEM (mm)  0.7 mm
Depth of Interaction (DOI) Yes – true DOI
Sensitivity  Up to 11% depending on configuration

CT Specifications

Power Output/Tube (W) 18 W
X-ray tube Voltage Range 40-90 kVp
X-ray tube Current Range  0.2 mA
Detector Pixel Matrix 1944 x 1536
Magnification  Up to 5.5x (variable zoom)
Spatial Resolution  Up to 18 μm
Voxel size Resolution Up to 5 μm
Low dose system Yes

Dimensions and weight with animal table

Total Weight PET/CT 466 kg
PET/CT Dimensions 1600 (h), 1100 (w), 2140 (l)
Overview PET/Ct technology

MRS*CLIP-ON Technology for PET/MR & PET/CT

MRS*PET/CT’s are based on the MRS*PET CLIP-ON technology. It is a unique plug and play concept making the same PET component compatible with CT and MR up to 9.4T. This modular approach offers significant advantages in efficiency and workflow, and most importantly, considerably reduces the investment for the research institute.

PET Technology: True Depth Of Interaction (DOI)

The MRS*PET for small animal imaging uses the latest silicon photomultiplier (SiPM) technology. The detector assembly (crystal/ SiPM) allows true DOI (depth of interaction) with two pixelated layers of scintillator crystals with different matrices. This design enables the MR SOLUTIONS PET module to reach under 0.8mm resolution.

 

CT Technology with variable zoom and dual energy

MRS*PET/CT 80 and MRS*PET/CT 120 have a variable zoom allowing high resolution up to 5μm. These systems are suitable for both in-vivo and ex-vivo applications.

Animal Handling

MRS*PET/CT’s use advanced animal handling and animal monitoring systems. Much more than a simple animal bed for preclinical imagers, the system provides a well-controlled environment for handling lab animals and plays a critical role in obtaining accurate and reproducible imaging results.

Preclinical Scan: Multimodality imaging Software

Preclinical Scan is the multimodality interface for preclinical imaging. Under one interface users have access to all MRI functionalities such as adjusting MRI pulse sequences parameters, but also have access to the PET, SPECT and CT extended functionalities.

We have designed the graphical user interface to be friendly and easy to set up, even for the new user. For the advanced user, real-time optimisation and advanced functionalities are available. Preclinical Scan software can be configured with different levels of access depending on the experience of designated users. Learn More